<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-02 04-41-52
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 56 dBuV YLEX
Pilot RDS Phase Difference
7.8 kHz 2.9 kHz 45 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 65 kHz 12415 0,7974
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,0 dBr 4,35 dBr 5,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 4:41, 2.04.2025
RT
"YleX Iltapäivä: Päivän parhaat "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6205, 6201, 6203, 6207
FM Scope Max at: 65 kHz MIN: 10 kHz % above 76 kHz: 0,7974 Acquired: 2025/04/02 4.40.48 Total samples: 12415 Equivalent time: 0:10:20 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000
FM Scope MAX: 5,3 dBr MIN: 2,0 dBr AVE: 4,35 dBr % above 12,2 dBr: 0,0 Last value: 3,1 dBr (2025/04/02 4.40.48) 04.26 04.28 04.30 04.32 04.34 04.36 04.38 04.40 0 2 4 6 Pm [dBr]